近视儿童配戴不同光学区直径的角膜塑形镜对视觉质量的影响

Effect of Back Optical Zone Diameter of Orthokeratology Lens on Visual Quality in Myopic Children

  • 摘要:
    目的 评估近视儿童配戴不同光学区直径的角膜塑形镜对视觉质量的长期影响。
    方法 本研究为一项前瞻性、随机、双盲临床对照试验的探索性分析,聚焦于分析视觉质量相关参数。共纳入8~12周岁的近视儿童66例,随机分配到光学区直径为6 mm的角膜塑形镜组(6 mm组)和光学区直径为5 mm的角膜塑形镜组(5 mm组)。在戴镜前(基线)和戴镜后1 d,1周,1、3、6、9、12个月进行访视。视觉质量检测指标包括裸眼视力、最佳矫正视力、对比敏感度(contrast sensitivity, CS)、高阶像差(high-order aberrations, HOA)、调制传递函数值(modulation transfer function value, MTF)、斯特列尔比值(Strayer ratio, SR)和视觉质量问卷。
    结果 共63名儿童完成随访,其中6 mm组33例,5 mm组30例。两组基线数据差异无统计学意义(P>0.05)。两组裸眼视力和最佳矫正视力在任何随访时间点差异均无统计学意义(P>0.05)。戴镜3个月后,5 mm组高空间频率(18 cpd)CS水平低于6 mm组(P=0.015),戴镜12个月后,两组间CS水平差异无统计学意义(P>0.05)。两组全眼和角膜总HOA、球差、彗差戴镜后均增加,5 mm组HOA高于6 mm组(P均<0.05)。戴镜3个月后,5 mm组MTF值和SR值低于6 mm组(P<0.05),戴镜12个月后,两组差异无统计学意义(P>0.05)。两组戴镜后视觉质量相关问卷评分差异无统计学意义(P>0.05)。
    结论 近视儿童配戴不同光学区直径角膜塑形镜后的主观满意度均提高,主观视觉质量无差异,但客观视觉质量均降低,其中5 mm组影响更大。

     

    Abstract:
    Objective To evaluate the long-term effects of orthokeratology (ortho-k) lenses with different back optical zone diameters (BOZD) on the quality of vision in myopic children.
    Methods We conducted an exploratory analysis based on a prospective, randomized, double-blind clinical trial, focusing on the parameters related to visual quality. A total of 66 myopic children aged 8 to 12 years were enrolled and randomly assigned to either a 6-mm BOZD ortho-k lens group (the 6 mm group) or a 5-mm BOZD ortho-k lens group (the 5 mm group). The participants were followed up at baseline, and at 1 day, 1 week, and 1, 3, 6, 9, and 12 months after lens wearing. Visual quality measurements included uncorrected visual acuity (VA), best corrected VA, contrast sensitivity (CS), high-order aberrations (HOA), modulation transfer function (MTF), Strayer ratio (SR), and visual quality questionnaire.
    Results A total of 63 children (33 children in the 6 mm group and 30 children in the 5 mm group) completed the study. There were no significant differences in baseline data between the two groups (P > 0.05). There were no significant differences in subjective uncorrected VA or best corrected VA between the two groups at any follow-up visit (P > 0.05). After wearing the lenses for 3 months, the CS at high spatial frequency (18 cpd) in the 5 mm group was lower than that in the 6 mm group (P = 0.015). However, at 12 months, no significant differences in the CS were found between the two groups (P > 0.05). The ocular and corneal total HOA, spherical aberration, and coma aberration in both groups increased after wearing the lenses, and the HOA in the 5 mm group was higher than that in the 6 mm group (all P< 0.05). After wearing the lenses for 3 months, the MTF and SR values in the 5 mm group were lower than those in the 6 mm group (P < 0.05). At 12 months, there was no significant difference between the two groups (P > 0.05). The vision-quality-related questionnaire scores showed no significant differences between the two groups (P > 0.05).
    Conclusion In myopic children, wearing ortho-k lenses with different BOZD results in improved subjective satisfaction, with no difference in subjective visual quality. However, objective visual quality declined in both groups, with a greater impact observed in the 5 mm group.

     

/