欢迎来到《四川大学学报(医学版)》
张坤, 张晞倩, 卢苇等. LC-MS/MS法测定人血浆中地氯雷他定与代谢物3-OH地氯雷他定浓度及其生物等效性研究[J]. 四川大学学报(医学版), 2015, 46(5): 783-787.
引用本文: 张坤, 张晞倩, 卢苇等. LC-MS/MS法测定人血浆中地氯雷他定与代谢物3-OH地氯雷他定浓度及其生物等效性研究[J]. 四川大学学报(医学版), 2015, 46(5): 783-787.
ZHANG Kun, ZHANG Xi-qian, LU Wei. et al. Determination of Desloratadine and Its Metabolite 3-OH Desloratadine in Human Plasma by LC-MS/MS[J]. Journal of Sichuan University (Medical Sciences), 2015, 46(5): 783-787.
Citation: ZHANG Kun, ZHANG Xi-qian, LU Wei. et al. Determination of Desloratadine and Its Metabolite 3-OH Desloratadine in Human Plasma by LC-MS/MS[J]. Journal of Sichuan University (Medical Sciences), 2015, 46(5): 783-787.

LC-MS/MS法测定人血浆中地氯雷他定与代谢物3-OH地氯雷他定浓度及其生物等效性研究

Determination of Desloratadine and Its Metabolite 3-OH Desloratadine in Human Plasma by LC-MS/MS

  • 摘要: 目的 建立液相色谱-串联质谱(LC-MS/MS)法测定人血浆中地氯雷他定及其代谢物3-OH地氯雷他定的浓度,并应用于两种地氯雷他定片的餐后人体生物等效性研究。方法 采用双周期随机交叉自身对照试验设计,24例健康男性受试者餐后分别单剂量口服两种地氯雷他定片5 mg,LC-MS/MS法测定血浆中地氯雷他定及其代谢物3-OH地氯雷他定的浓度,以Winnonlin6.3软件计算主要药动学参数,并评价两种地氯雷他定片的餐后生物等效性。结果 地氯雷他定和3-OH地氯雷他定标准曲线范围均为0.050~6.0 ng/mL,批内、批间相对标准偏差均在15%以内。地氯雷他定和3-OH地氯雷他定峰浓度(Cmax)、药时曲线下面积(AUC0-tAUC0-∞的90%置信区间均在80%~125%等效区间之内,达峰时间(tmax)经非参数秩和检验,不同制剂间差异无统计学意义( P>0.05)。结论 所建立的LC-MS/MS方法适用于人血浆中地氯雷他定及其代谢物3-OH地氯雷他定浓度的同时测定,并可以用于地氯雷他定片生物等效性的评价。

     

    Abstract: Objective To develop a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of desloratadine and its metabolite 3-OH desloratadine in human plasma. Methods 24 healthy male volunteers received a single oral dose of 5 mg desloratadine tablets in a randomized crossover bioequivalence study with two preparations of tablets. Serial plasma samples were taken and analyzed by the LC-MS/MS method. The pharmacokinetic parameters of the two preparations were calculated and compared statistically to evaluate their bioequivalence using Winnonlin 6.3. Results The calibration curves of desloratadine and 3-OH desloratadine were both linear over the concentration range of 0.050-6.0 ng/mL, with intra-batch and inter-batch relative standard deviations less than 15%. The 90% confidence intervals (CIs) of peak concentration (Cmax),area under the curve (AUC0-t and AUC0-∞ of desloratadine and 3-OH desloratadine all resided within the bioequivalence limit 80%-125%. No significant difference in peak time (tmax) was demonstrated between the two preparations. Conclusion The LC-MS/MS method can be used for simultaneous determination of desloratadine and 3-OH desloratadine in human plasma, which has been successfully applied to a bioequivalence study.

     

© 2015 《四川大学学报(医学版)》编辑部 版权所有 cc

开放获取 本文遵循知识共享署名—非商业性使用4.0国际许可协议(CC BY-NC 4.0),允许第三方对本刊发表的论文自由共享(即在任何媒介以任何形式复制、发行原文)、演绎(即修改、转换或以原文为基础进行创作),必须给出适当的署名,提供指向本文许可协议的链接,同时标明是否对原文作了修改;不得将本文用于商业目的。CC BY-NC 4.0许可协议详情请访问 https://creativecommons.org/licenses/by-nc/4.0

/

返回文章
返回