欢迎来到《四川大学学报(医学版)》
吴瑕, 胥劲, 倪建, 等. 稀释曲线法评价TgAb对Tg测定的干扰[J]. 四川大学学报(医学版), 2013, 44(3): 432-435.
引用本文: 吴瑕, 胥劲, 倪建, 等. 稀释曲线法评价TgAb对Tg测定的干扰[J]. 四川大学学报(医学版), 2013, 44(3): 432-435.
WU Xia, XU Jin, NI Jian, et al. TgAb Interference with Experimental Tg Values Detected by Dilution Curves[J]. Journal of Sichuan University (Medical Sciences), 2013, 44(3): 432-435.
Citation: WU Xia, XU Jin, NI Jian, et al. TgAb Interference with Experimental Tg Values Detected by Dilution Curves[J]. Journal of Sichuan University (Medical Sciences), 2013, 44(3): 432-435.

稀释曲线法评价TgAb对Tg测定的干扰

TgAb Interference with Experimental Tg Values Detected by Dilution Curves

  • 摘要: 目的 探讨稀释曲线法评价分化型甲状腺癌(DTC)患者内源性甲状腺球蛋白抗体(TgAb)对甲状腺球蛋白(Tg)测定的干扰。 方法 用血清稀释液、6例DTC患者可测浓度的TgAb血清(TgAb 20~25 IU/mL、Tg<0.1 μg/L)、5例DTC患者不可测浓度TgAb血清(TgAb<10 IU/mL、Tg<0.1 μg/L)分别稀释另外6例DTC患者的Tg血清(TgAb<10 IU/mL、Tg>10 μg/L),三明治夹心法(IMA)测定各稀释管Tg值。以各稀释管Tg理论值为横坐标、实测值为纵坐标,绘制稀释曲线图。 结果 血清稀释液稀释DTC患者Tg血清,稀释曲线呈直线。6例可测浓度TgAb血清分别稀释6例DTC患者Tg血清,获得36条稀释曲线,其中12条呈直线,24条不呈直线;同一可测浓度TgAb血清稀释不同患者Tg血清,仅部分呈直线;不同患者TgAb血清稀释同一患者Tg血清,仅部分呈直线。5例不可测浓度TgAb血清稀释3例患者Tg血清,只完成稀释曲线11条,仅4条呈直线,7条不呈直线。 结论 同一患者的TgAb稀释多例患者的Tg血清,部分有干扰。不可测浓度TgAb也可能干扰其他患者的Tg测定。稀释曲线法仅可间接评价DTC患者自身TgAb是否干扰Tg测定。

     

    Abstract: Objecitve To identify the interference of endogenous antithyroglobulin (TgAb) with experimental thyroglobulin (Tg) values using dilution curves. Methods Dilution buffer, detectable TgAb serums (TgAb 20-25 IU/mL, Tg free) and undetectable TgAb serums (TgAb <10 IU/mL, Tg free) were employed to dilute the Tg serums from patients with DTC, respectively. The Tg values were detected by immunometric assay (IMA). The experimental Tg values (Y-axis) were plotted against expected serum Tg values (X-axis). Diluted curves were used to evaluate the interference of TgAb on the experimental Tg values. A linear dilution curve is supposed to appear if no TgAb interference exists. Results The Tg dilution curves with dilution buffer were linear. Thirty six dilution curves were obtained with TgAb serums from six patients diluted by detectable TgAb serums, and 12 showed linear. Tg serums from six patients diluted by one detectable TgAb serum resulted in both linear and non-linear results. One Tg serum diluted by six TgAb serums also resulted both linear and non-linear results. Tg serums from three patients diluted by five undetectable TgAb serums resulted in 11 dilution curves, four of which were linear. Conclusion Dilution curves can be used to predict TgAb interference indirectly. Detectable TgAb may not interfere with experimental Tg values. Whereas, undetectable TgAb may interfere with Tg values. TgAb could not be used to predict Tg interference. Key words Differentiated thyroid cancer Thyroglobulin

     

© 2013 《四川大学学报(医学版)》编辑部 版权所有 cc

开放获取 本文遵循知识共享署名—非商业性使用4.0国际许可协议(CC BY-NC 4.0),允许第三方对本刊发表的论文自由共享(即在任何媒介以任何形式复制、发行原文)、演绎(即修改、转换或以原文为基础进行创作),必须给出适当的署名,提供指向本文许可协议的链接,同时标明是否对原文作了修改;不得将本文用于商业目的。CC BY-NC 4.0许可协议详情请访问 https://creativecommons.org/licenses/by-nc/4.0

/

返回文章
返回