Welcome to JOURNAL OF SICHUAN UNIVERSITY (MEDICAL SCIENCES) May 26, 2025
CHEN Xiao-hang, XIONG Yan, WANG Jiang-lan, et al. Prospective Study on Corneal Safety Evaluation of Children/Adolescents with Low and Moderate Myopia after Long-Term Orthokeratology[J]. Journal of Sichuan University (Medical Sciences), 2021, 52(6): 1006-1010. DOI: 10.12182/20211160107
Citation: CHEN Xiao-hang, XIONG Yan, WANG Jiang-lan, et al. Prospective Study on Corneal Safety Evaluation of Children/Adolescents with Low and Moderate Myopia after Long-Term Orthokeratology[J]. Journal of Sichuan University (Medical Sciences), 2021, 52(6): 1006-1010. DOI: 10.12182/20211160107

Prospective Study on Corneal Safety Evaluation of Children/Adolescents with Low and Moderate Myopia after Long-Term Orthokeratology

More Information
  • Corresponding author:

    LIU Long-qian, E-mail: b.q15651@hotmail.com

  • Received Date: July 29, 2021
  • Revised Date: October 07, 2021
  • Available Online: November 28, 2021
  • Published Date: November 19, 2021
  •   Objective   To observe the possible changes in the integrity of the cornea and corneal endothelial cells of children/adolescents with low or moderate myopia after long-term wearing of orthokeratology (ortho-k) lenses, as well as the time when the relevant changes occur, so as to evaluate the safety of long-term wearing of ortho-k lens and to provide a reference for the safety evaluation of subjects wearing ortho-k lenses.
      Methods   Subjects were recruited in the Contact Lens Clinic, West China Hospital, Sichuan University for a three-year prospective study. Ortho-k of the same brand was matched for the subjects. The central corneal thickness (CCT), corneal endothelial cell density (ECD), and hexagonal cell ratio (HEX) were measured prior to the wearing of ortho-k lenses and after wearing ortho-k lenses for 1 month, 3 months, 6 months, and every 3 months until 36 months. The results of corneal fluorescence staining were recorded during each follow-up. When corneal staining was observed, the Efron grading standard was used for grading and corresponding treatment was given.
      Results   A total of 33 (66 eyes) myopic patients were included in the study. 15 cases (46.2%) reported having binocular foreign body sensations and tearing within the first week of wearing the lenses. After the subjects became adapted to wearing the lenses, the symptoms disappeared without intervention. During the follow-up period, 31 cases (93.94%) of binocular corneal staining were observed, of which, 24 cases (72.73%) were graded as G0, receiving no treatment, 5 cases (15.15%) were graded as GⅠ, and 2 cases (6.06%) were graded as GⅡ. Corresponding clinical treatment for corneal staining was given to the GⅠ and GⅡ subjects. This study found that the corneal ECD was inversely proportional to age (r=-0.380, P=0.002). During the three-year follow-up period, the subjects’ left eye ECD decreased from the baseline at 24 months and the right eye ECD decreased from the baseline at 27 months (P<0.05). The CCT results in the subjects showed that CCT became thinner at 1 month after wearing the lens (P<0.05), but the follow-up CCT showed a stable trend.
      Conclusion   After three years of long-term follow-up, no serious corneal complications occurred in children/adolescents with moderate and low myopia after long-term wearing of ortho-k lens. The corneal ECD of both eyes started decreasing 24 months after wearing the ortho-k lenses and the CCT decreased 1 month after wearing the lenses.
  • [1]
    KHORRAMI-NEJAD M, MORADI R, AKBARZADEH B A, et al. Effect of axial length and anterior chamber depth on the peripheral refraction profile. Int J Ophthalmol,2021,14(2): 292–298. DOI: 10.18240/ijo.2021.02.17
    [2]
    LLIMORE M A, JOHNSON L A. Overnight orthokeratology. Cont Lens Anterior Eye,2020,43(4): 322–332. DOI: 10.1016/j.clae.2020.03.018
    [3]
    HIRAOKA T, KAKITA T, OKAMOTO F, et al. Long-term effect of overnight orthokeratology on axial length elongation in childhood myopia: A 5-year follow-up study. Invest Ophthalmol Vis Sci,2012,53(7): 3913–3919. DOI: 10.1167/iovs.11-8453
    [4]
    KAKITA T, HIRAOKA T, OSHIKA T. Influence of overnight orthokeratology on axial elongation in childhood myopia. Invest Ophthalmol Vis Sci,2011,52(5): 2170–2174. DOI: 10.1167/iovs.10-5485
    [5]
    CHO P, CHEUNG S W. Retardation of myopia in orthokeratology (ROMIO) study: A 2-year randomized clinical trial. Invest Ophthalmol Vis Sci,2012,53(11): 7077–7085. DOI: 10.1167/iovs.12-10565
    [6]
    TSENG C H, FONG C F, CHEN W L, et al. Overnight orthokeratology-associated microbial keratitis. Cornea,2005,24(7): 778–782. DOI: 10.1097/01.ico.0000153101.81657.0b
    [7]
    WILHELMUS K R. Acanthamoeba keratitis during orthokeratology. Cornea,2005,24(7): 864–866. DOI: 10.1097/01.ico.0000175410.28859.bd
    [8]
    YEPES N, LEE S B, HILL V, et al. Infectious keratitis after overnight orthokeratology in Canada. Cornea,2005,24(7): 857–860. DOI: 10.1097/01.ico.0000154388.43501.f8
    [9]
    HSIAO C H, LIN H C, CHEN Y F, et al. Infectious keratitis related to overnight orthokeratology. Cornea,2005,24(7): 783–788. DOI: 10.1097/01.ico.0000175412.13612.8a
    [10]
    姜珺, 瞿小妹, 杨晓, 等. 非球面角膜塑形镜矫正近视的有效性和安全性. 中华眼视光学与视觉科学杂志,2020,22(8): 575–581. DOI: 10.3760/cma.j.cn115909-20190723-00206
    [11]
    艾欣, 张学辉, 叶璐. 角膜塑形镜控制青少年近视有效性及安全性的Meta分析. 中华眼视光学与视觉科学杂志,2019,21(2): 127–134. DOI: 10.3760/cma.j.issn.1674-845X.2019.02.009
    [12]
    CHEUNG S W, CHO P. Does a two-year period of orthokeratology lead to changes in the endothelial morphology of children? Cont Lens Anterior Eye,2018,41(2): 214–218. DOI: 10.1016/j.clae.2017.10.006
    [13]
    NIETO-BONA A, GONZALEZ-MESA A, NIETO-BONA M P, et al. Long-term changes in corneal morphology induced by overnight orthokeratology. Curr Eye Res,2011,36(10): 895–904. DOI: 10.3109/02713683.2011.593723
    [14]
    KIM W K, KIM B J, RYU I H, et al. Corneal epithelial and stromal thickness changes in myopic orthokeratology and their relationship with refractive change. PLoS One, 2018, 13(9): e0203652[2021-09-30]. https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0203652. doi: 10.1371/journal.pone.0203652.
    [15]
    王帅, 胡琦, 崔静, 等. 角膜塑形镜对角膜的组织学影响. 中国斜视与小儿眼科杂志,2017,25(1): 17–19. DOI: 10.3969/J.ISSN.1005-328X.2017.01.005
    [16]
    国际角膜塑形学会亚洲分会. 中国角膜塑形用硬性透气接触镜验配管理专家共识(2016年). 中华眼科杂志,2016,52(5): 325–327. DOI: 10.3760/cma.j.issn.0412-4081.2016.05.002
    [17]
    EFRON N. Grading scales for contact lens complications. Ophthalmic Physiol Opt,1998,18(2): 182–186. DOI: 10.1016/S0275-5408(97)00066-5
    [18]
    NG L H. Central corneal epitheliopathy in a long-term, overnight orthokeratology lens wearer: A case report. Optom Vis Sci,2006,83(10): 709–714. DOI: 10.1097/01.opx.0000236813.39603.49
    [19]
    STILLITANO I, MAIDANA E, LUI M, et al. Bubble and corneal dimple formation after the first overnight wear of an orthokeratology lens: A case series. Eye Contact Lens,2007,33(5): 253–258. DOI: 10.1097/01.icl.0000252870.05807.ea
    [20]
    NG L H. Corneal foreign body injury during overnight orthokeratology lens wear: A case report. Cont Lens Anterior Eye,2008,31(3): 158–160. DOI: 10.1016/j.clae.2008.01.006
    [21]
    陈建卓, 陈露, 李媛媛, 等. 角膜塑形镜423例临床应用报告. 国际眼科杂志,2012,12(1): 130–132. DOI: 10.3969/j.issn.1672-5123.2012.01.43
    [22]
    LIU Y M, XIE P. The safety of orthokeratology—A systematic review. Eye Contact Lens,2016,42(1): 35–42. DOI: 10.1097/ICL.0000000000000219
    [23]
    吕岚, 邹留河, 王荣光, 等. 角膜塑形术致感染性角膜溃疡的临床分析. 中华眼科杂志,2001,37(6): 443–446. DOI: 10.3760/j:issn:0412-4081.2001.06.013
    [24]
    王跃静, 陈独娅, 成伟, 等. 角膜塑形镜治疗近视的临床观察和并发症分析. 国际眼科杂志,2010,10(8): 1582–1584.
    [25]
    姜超, 侯文博, 王智群, 等. 角膜塑形镜相关阿米巴性角膜炎一例. 中华眼视光学与视觉科学杂志,2012,14(2): 120–121.
    [26]
    BULLIMORE M A, SINNOTT L T, JONES-JORDAN L A. The risk of microbial keratitis with overnight corneal reshaping lenses. Optom Vis Sci,2013,90(9): 937–944. DOI: 10.1097/OPX.0b013e31829cac92
    [27]
    KAM K W, YUNG W, LI G, et al. Infectious keratitis and orthokeratology lens use: A systematic review. Infection,2017,45(6): 727–735. DOI: 10.1007/s15010-017-1023-2
    [28]
    王丽纯, 张钰, 陈跃国. 夜戴角膜塑形镜对青少年角膜内皮细胞的影响. 中华眼视光学与视觉科学杂志,2019,21(9): 677–681.
    [29]
    谢培英, 郭曦. 角膜塑形术矫治近视眼的新进展. 中华眼科杂志,2021,57(4): 315–318.
    [30]
    夏元, 王春红, 杨丽萍. 配戴夜戴型角膜塑形镜两年后角膜激光共聚焦显微镜观察. 中华眼视光学与视觉科学杂志,2014,16(2): 81–83.
    [31]
    郭曦, 谢培英. 青少年近视眼患者配戴角膜塑形镜七年的角膜厚度和内皮观察. 中华眼科杂志,2014,50(1): 9–13. DOI: 10.3760/cma.j.issn.0412-4081.2014.01.004
    [32]
    BEUSCHEL R, HOFMANN T, MESSERLI J. Is the decrease in corneal endothelial cell density in relation to age linear? Klin Monbl Augenheilkd,2015,232(4): 375–379. DOI: 10.1055/s-0035-1545816
    [33]
    GALGAUSKAS S, NORVYDAITE D, KRASAUSKAITE D, et al. Age-related changes in corneal thickness and endothelial characteristics. Clin Interv Aging,2013,8: 1445–1450. DOI: 10.2147/CIA.S51693
    [34]
    吕燕云, 武晶晶, 彭丽, 等. 青少年近视性屈光参差患者长期配戴角膜塑形镜效果观察. 眼科,2017,26(2): 131–134.
    [35]
    SWARBRICK H A. Orthokeratology (corneal refractive therapy): What is it and how does it work? Eye Contact Lens,2004,30(4): 181–185. DOI: 10.1097/01.icl.0000140221.41806.6e
    [36]
    ZHU M J, FENG H Y, HE X G, et al. The control effect of orthokeratology on axial length elongation in Chinese children with myopia. BMC Ophthalmol, 2014, 14: 141[2021-09-30]. https://bmcophthalmol.biomedcentral.com/articles/10.1186/1471-2415-14-141. doi: 10.1186/1471-2415-14-141.
  • Cited by

    Periodical cited type(11)

    1. 常胜,杨宏建,张利敏. 曲面设计与常规角膜塑形镜对青少年近视的治疗效果. 菏泽医学专科学校学报. 2025(01): 25-28 .
    2. 宋逸飞,张敏,刘丹,宋光明,侯俊丽,王艳昭,杨芝芽,吕晗,袁沛宏,戎萍. 明目归源推拿术治疗学龄期儿童单纯性近视临床疗效观察. 辽宁中医杂志. 2025(04): 91-96+222-223 .
    3. 陈亮,李元龙,王怡,石磊. 角膜缘干细胞移植联合手术切除治疗对翼状胬肉患者角膜散光度、视力及泪膜功能的影响. 转化医学杂志. 2024(07): 1040-1044 .
    4. 兰芳,王艳青,常胜. 佩戴角膜塑形镜和框架眼镜对近视者的防控效果研究. 中华眼外伤职业眼病杂志. 2024(11): 816-822 .
    5. 马薇,杨必,王雪,刘陇黔. 近视儿童配戴离焦软性接触镜与角膜塑形镜的安全性和有效性的观察比较. 四川大学学报(医学版). 2023(01): 181-185 .
    6. 邢晓花,王晓亚,汪三慧,涂静. 角膜塑形镜矫治患者停戴时长对屈光状态和角膜内皮细胞的影响. 国际眼科杂志. 2023(04): 655-659 .
    7. 邢建男,何伟,张珊. 配戴角膜塑形镜患者发生角膜上皮点状染色的影响因素. 国际眼科杂志. 2023(06): 981-985 .
    8. 黄颉,刘阳园,杨柳,李超华,陈水玲,林瑞杰. 消旋山莨菪碱滴眼液联合角膜塑形镜治疗青少年近视患者的效果观察. 华夏医学. 2023(06): 121-124 .
    9. 祁海燕. 角膜塑形镜对青少年儿童近视的矫正效果及对角膜形态与屈光度的影响研究. 名医. 2022(09): 54-56 .
    10. 王宏. 长期配戴角膜塑形镜治疗近视的疗效及角膜并发症临床分析. 中国医疗器械信息. 2022(17): 149-151 .
    11. 王莹,吴晓兰,周磊,金霞,忻丹丽,张晓瑾. 减少旁中心离焦软镜治疗儿童近视的疗效及对屈光度、眼轴长度的影响. 中华全科医学. 2022(11): 1863-1865+1869 .

    Other cited types(1)

Catalog

    Article views (1348) PDF downloads (69) Cited by(12)

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return