不同光学微结构设计镜片用于近视儿童的临床研究

Clinical Study on the Use of Lenses With Different Optical Microstructure Designs in Children With Myopia

  • 摘要:
    目的 比较不同光学微结构设计镜片,即多区正向光学离焦(defocus incorporated multiple segments, DIMS)、高非球面微透镜(highly aspherical lenslets, HAL)和降低对比度点扩散(diffusion optics technology, DOT)三种设计镜片对近视儿童的防控效果。
    方法 多中心回顾性队列研究。收集2024年5月—2025年12月期间,在四川大学华西医院、武侯华西利康视光诊所、美视康眼科视光中心和成都小艾眼科门诊就诊验光及复查随访的配戴微结构设计框架镜片的近视儿童的临床资料,共纳入210例(210只右眼)近视儿童,每组70例,分别为DIMS组、HAL组和 DOT组。观察随访时间为配戴镜片后6个月和12个月。比较和分析三组的眼轴长度和屈光度的变化。
    结果 三组在年龄、性别分布、屈光度、眼轴长度、散光等指标上差异均无统计学意义,组间基线具有良好的均衡性。主要指标眼轴长度比较,组别(F=8.629, P<0.001)和时间(F=165.150, P<0.001)的主效应均显著,且组别与时间的交互效应亦有统计学意义(F=4.754, P=0.010);戴镜6个月和12个月后,DOT组的眼轴增长量(均数)(6个月:-0.02 mm;12个月:0.03 mm)低于HAL组(6个月:0.05 mm;12个月:0.13 mm)和DIMS组(6个月:0.03 mm;12个月:0.13 mm)(P<0.05)。等效球镜度(spherical equivalent refraction, SER)组别主效应显著(F=5.311, P=0.006),戴镜6个月和12个月后DOT组的度数增加量均少于其他两组(P<0.05)。主觉验光总散光的时间主效应显著(F=11.802, P=0.001),而组别(F=2.961, P=0.054)及组别与时间的交互作用(F=0.323, P=0.725)的影响均无统计学意义,不同镜片对散光的影响趋势在观察期内基本一致。
    结论 三种光学微结构设计镜片均能延缓眼轴长度和近视的增加,DOT设计近视防控效果更明显。配戴后近视儿童主觉验光散光轻微增加,无临床意义。

     

    Abstract:
    Objective  Compare the effectiveness of three different optical microstructure lens designs—defocus- incorporated multiple segments (DIMS), highly aspherical lenslets (HAL), and diffusion optics technology (DOT)—in controlling myopia progression in children.
    Methods  This multicenter retrospective cohort study collected clinical data from myopic children wearing microstructure-designed spectacle lenses who visited West China Hospital of Sichuan University, Wuhou West China Likang Optometry Clinic, Meishi Kang Eye Optometry Center, and Chengdu Xiaoai Eye Clinic for refraction and follow-up between May 2024 and December 2025. A total of 210 myopic children (210 right eyes) were enrolled and equally divided into three groups: DIMS group, HAL group, and DOT group, with 70 cases in each group. Follow-up evaluations were conducted at 6 and 12 months after lens wear. Changes in axial length and refractive error were compared and analyzed among the three groups.
    Results  There were no statistically significant differences among the three groups in age, gender distribution, refractive power, axial length, astigmatism, etc. The baseline characteristics of the groups were well balanced. For axial length, the main effects of group (F = 8.629, P < 0.001) and time (F = 165.150, P< 0.001) were both significant, and the interaction between group and time was also statistically significant (F = 4.754, P = 0.010). After 6 and 12 months of wearing glasses, axial elongation (mean) in the DOT group (6 months: -0.02 mm; 12 months: 0.03 mm) was lower than in the HAL group (6 months: 0.05 mm; 12 months: 0.13 mm) and the DIMS group (6 months: 0.03 mm; 12 months: 0.13 mm) (P < 0.05). The main effect of group for spherical equivalent refraction (SER) was significant (F = 5.311, P = 0.006), and the increase in myopic diopters in the DOT group after 6 and 12 months of wearing glasses was smaller than in the other two groups (P < 0.05). For subjective refraction of total astigmatism, the main effect of time was significant (F = 11.802, P = 0.001), whereas the effects of group (F = 2.961, P = 0.054) and the interaction between group and time (F = 0.323, P = 0.725) were not statistically significant. The pattern of the effect of different lenses on astigmatism was essentially consistent over the observation period.
    Conclusion  All three types of optical microstructure-designed lenses can delay elongation of the ocular axis and progression of myopia. The DOT design shows a more significant effect in preventing myopia. After wearing these lenses, the subjective refraction of myopic children shows a slight increase in astigmatism, but this has no clinical significance.

     

/