XU Xu, ZHANG Jin-ge, PENG Wan-lin, et al. Application of 3.0T Time-of-flight Magnetic Resonance Angiography with Sparse Undersampling and Iterative Reconstruction in the Diagnosis of Unruptured Intracranial Aneurysms[J]. Journal of Sichuan University (Medical Sciences), 2021, 52(1): 92-97. DOI: 10.12182/20210160602
Citation: XU Xu, ZHANG Jin-ge, PENG Wan-lin, et al. Application of 3.0T Time-of-flight Magnetic Resonance Angiography with Sparse Undersampling and Iterative Reconstruction in the Diagnosis of Unruptured Intracranial Aneurysms[J]. Journal of Sichuan University (Medical Sciences), 2021, 52(1): 92-97. DOI: 10.12182/20210160602

Application of 3.0T Time-of-flight Magnetic Resonance Angiography with Sparse Undersampling and Iterative Reconstruction in the Diagnosis of Unruptured Intracranial Aneurysms

  •   Objective  To evaluate the diagnostic value of 3.0T time-of-flight MR angiography with sparse undersampling and iterative reconstruction (TOFu-MRA) for unruptured intracranial aneurysms (UIAs) on the basis of using digital subtraction angiography (DSA) as the reference standard.
      Methods  A total of 65 patients with suspected UIAs were prospectively enrolled and all patients underwent TOFu-MRA and DSA. Relying on DSA as the reference standard, the sensitivity (SEN), specificity (SPE), positive predictive value (PPV) and negative predictive value (NPV) of using TOFu-MRA in UIA diagnosis were calculated, and the inter-observer agreement between two doctors was determined. Comparison of maximum intensity projection (MIP) and volume rendering (VR) image datasets was made to evaluate the agreement between DSA results and TOFu-MRA in the measurement of UIA morphological parameters, including the neck width (Dneck), height (H) , and width (Dwidth) of UIAs.
      Results  The study covered 55 UIAs from 46 patients. The SEN, SPE, PPV and NPV of the two doctors using TOFu-MRA in UIA diagnosis were as follows: (95.7%, 95.7%), (94.7%, 94.7%), (97.8%, 97.8%) and (90.0%, 90.0%), respectively for patient-based assessment; (96.4%, 94.5%), (94.7%, 94.7%), (98.1%, 98.1%) and (90.0%, 85.7%), respectively, for aneurysm-based assessment. There is a strong inter-observer agreement (Kappa=0.93 for patient-based assessment and 0.96 for aneurysm-based assessment) between the two doctors. Moreover, Bland-Altman analysis showed that more than 95% points fell within the limits of agreement (LoA), suggesting strong agreement between the two examination methods for the measurement of UIAs morphological parameters.
      Conclusion  TOFu-MRA showed good diagnostic efficacy for UIAs and the results were in good agreement with those of DSA, the reference standard, for assessing UIA morphological parameter. TOFu-MRA can be used as a first choice for noninvasive diagnostic evaluation of UIAs.